8028 SIP Doorphone

Specifications

Item Description
Compatibility SIP
Configuration Web Interface (HTTP) or Provisioning (TFTP, FTP, HTTP)
NAT STUN, CRLF Keep Alive
Speech Full Duplex Capable
Codec G.711
Physical Separate Controller and Door Station
Weight
3.1 lb (1.4 kg)
Compliance
EN60950:2001, IEEE 802.3, RFC3261 (SIP), RoHS, CE, FCC Class B, CISPR 22 Class B, CISPR 24, CSA/UL (USA & Canada)
Controller
Power AC Mains Adapter 95-230V 50/60Hz Included
Indicators Power, Door Station Status, In-Use, Door Unlock
Network Connection RJ45 Jack
Installation Shelf or wall mounted
Environmental Dry indoor location
Door Control Connection 5 Position terminal strip
Door Control Power Available 24V DC, 300mA Strike power +/-
Door Control Relay Relay C, NO, NC phone keypad activated; Maximum 30V, 1A
Door Station Connection RJ12 Jack Center Pair
Door Station Wiring 24 AWG Twisted Pair to 1000 Ft (300 m)
Auxiliary Input Connection RJ12 Jack Second Pair
Auxiliary Input Electrical Detects dry contact closure 24V 4mA sensing current
Auxiliary Input Functions Manual door release; Door control lockout; Door sensor NC (Default) or NO; Call button NC or NO; Disabled
Auxiliary Output Connection RJ12 Jack Outside Pair
Auxiliary Output Electrical Normally open switch 180 Ohms active; Maximum 30V, 50mA
Auxiliary Output Functions In-Use (Default); Ringing; Call button pressed; Door unlock; Door open (requires door sensor); Door alarm (requires door sensor); Door sensor NC (Default) or NO; Follow Controller input; Follow Door Station input; Disabled
Door Station
Power Provided by Controller link
Wiring Up to 1000 Ft (300 m) 24 AWG single twisted pair to controller
Signalling Digital link - bi-directional voice and data
Call Button Backlit tactile silicon rubber
Connections 6 Position terminal strip - Controller, Aux In, Aux Out
Installation Flush or surface mounted using supplied plastic bezel; Fits two gang electrical box
Environmental NEMA 3R Rated for outdoor locations; Ambient temperature -30 to +60° C.
Auxiliary Input Functions Door sensor NC or NO; Call button NC or NO (Default); Disabled
Auxiliary Input Electrical Detects dry contact closure 5V, 1mA sensing current
Auxiliary Output Functions In-Use; Ringing; Call button pressed (Default); Door/gate unlock; Door open (requires door sensor); Door alarm (requires door sensor); Door sensor NC (Default) or NO; Follow Controller input; Follow Door Station input; Disabled
Auxiliary Output Electrical Normally open switch 180 Ohms active; Maximum 30V, 50mA

Product Dimensions

Door Station

8028 Door Station

Controller

8028 Controller

 

  • In the interests of continual product development, specifications are subject to change without notice. Some features may only be available in specific firmware or hardware releases. 